call images

Call us

+919486763255

HVAC Cooling Tower

HVAC Cooling Tower

5000-100000 INR/Unit

Product Details:

X

HVAC Cooling Tower Price And Quantity

  • 5000-100000 INR/Unit
  • INR/Unit
  • 5000.00 - 10000.00 INR/Unit
  • 1 Unit

HVAC Cooling Tower Trade Information

  • Chennai, Cochin, Tuticorin
  • 3 Unit Per Week
  • 2 Days
  • As per Client Requirements
  • South India
  • ISO 9001:2008 Certified organization

Product Description

We are eminent manufacturers, suppliers and exporters of a wide range of HVAC Cooling Tower. These cooling towers are used for effective removal of heat and cooling buildings, these products are used by various industries like oil refineries, thermal power stations, petrochemical & chemical plants and HVAC systems. These products are wide accredit for their durability, easy installation, low maintenance, resistance against corrosion and high strength, these products are widely appreciated by our huge clientele. HVAC Cooling Tower are available in different models as per clients specific requirement.


Salient Features of HVAC Cooling Tower

  • A series of 30 models are available with multi-cell options
  • In single cell construction, its capacity is 10RT-1000RT
  • For less capacities, there is a direct drive system
  • Package Tower up to 80 Refrigeration Tonnage (RT)
  • Easy installation with simple, compact designs
  • Quick after sales support backed with ex-stock delivery
  • Various parts that have latest designs are Drive System, FRP Fan Assembly, Nozzles, PP EASY Clean Ring Fills, PVC Block Fills and PVC Eliminators.

What is HVAC Cooling Tower?

A cooling tower generates low temperature liquid using electricity or evaporation of water and releases the heat via cooling fins on the back of the refrigerator. Then it goes via expansion device where the pressure is suddenly low and the liquid turns into vapor and gives cooling effect. The transmitting water can be used in different activities like, chemical plants, air-conditioning and oil refinery etc. later the heat is drawn out from the atmosphere.

Cooling Towers are very light in weight, durable in use, less makeup volume, easy to install, power saving, low maintenance, easy to clean and corrosion resistant. Further, it has a very unique design, circular in shape and non rusting FRP basin & casing, Prevailing Wind Directions will not affect tower performance.

Characteristics of HVAC Cooling Tower

  • Installation on roof tops is also possible
  • Power saving and Non deteriorating
  • Resistance to corrosion and enhanced operating life
  • Simple to install and very less maintenance
  • Sturdy construction, less weight, least clearance and reduced make up volume

Design Features of HVAC Cooling Tower

  • Circular Shape
  • FRP Casing as well as Basin are constructed in non-rusting manner
  • No special installation is required
  • Wind Directions and Speeds does not effects the performance of these towers

Advantages:

  • lowest operating costs
  • No scale formation
  • Cleaning of heat exchangers not required
  • Reliability
  • Less maintenance
  • Rust resistant
  • Low Maintenance effort
  • Mainly visual checks
  • No consumable fill
  • No partition walls
  • Ease of access
  • Fan motor
  • Drive belt
  • Heat exchangers
  • Minimal movable parts that is fan and motor
  • Ease of cleaning
  • 1.700 psig pressurized water in any angle
  • Chemical cleaning possible, if required
  • Reliable operation
  • High quality
  • Meets EMC requirements
  • Innovative design
  • Unique corrosion protection
  • Closed cooling water loop
  • Reduced potential downtime
  • Ease of use
  • Minimum installation works
  • Ease of maintenance
  • Straight forward control system
  • Ideal for low temperature applications

Technical Specifications:

Product Name Cooling Tower
Design Specification Capacity 300m3/h
Water Flow Rate 300m3/h
Approach of cooling water 4 C
Inlet Water Temp 55 C
LVG.Water Temp 33 C
Ambient Air Temp.WB 28 C
Water cooling range 10 C
Ambient Air Temp.DRY 31.5 C
Evaporation Loss  of flow rate 0.6
Dimension 5.3 x 3.5 x 6.2m
Weight Dry Weight 4.55ton
Operation Weight 6.75ton
Basin Defined by user
Fan Type of Fan Propeller type fan W
/Fixed pitch
Drive system Belt Drive
Fan diameter and NO.of piece 3800/4mm/piece
Fan rate 231000m3/h
Max. wind load  
Motor Motor Type Vertical
Supply Vlt/Phase/Hz 380/50V/Hz
1piece
Pipe Inlet Hole 300mm
Outlet Pipe 350mm
Overflow Pipe 50mm
Material Steel material Q235 with FRP Anti-corrosion wrapped outside
Casing FRP
Fan casing Cast steel
Fan blade FRP
Distribution Mortar tank
Water basin Mortar tank
Louver FRP
Filling No-Padding
Specifications
Pipe Q235 with FRP Anti-corrosion wrapped outside
Bolt Q235 galvanized
Type of Distribution Spraying
Anti-corrosion  
Color Fruit green
Standard attach V-belt


To Know More About Our Products, Please Contact Us Here

Enter Buying Requirement Details
Email Id
Mobile number

Other Products in 'Cooling Towers' category



We mainly deals in Andhra Pradesh, Karnataka, Kerala, Puducherry, Tamil Nadu and Telangana only.
Back to top